sc127Aficio 1022
Ricoh Aficio 1022 Error SC127: Scan Sync Failure
The Ricoh Aficio 1022 error SC127 is a communication/sync failure within the exposure module.
1 views
Common causes
- 1Damaged flat scanner cable.
- 2Faulty CCD sensor.
- 3Electric noise.
- 4Exposure lamp fault.
Solutions
Diagnóstico rápido
Occurs during startup self-test. The sensor fails to send valid brightness signals.Solución paso a paso
- Restart unit.
- Check flat cable for cuts/damage.
- Check power supply to CIS/CCD unit.
Prevención y mantenimiento
Optic cleaning. Stable power.Cuándo llamar a un técnico
If the flat cable is broken, professional service is mandatory.Ficha técnica del equipo
- Tech: Copier.
- Speed: 22 cpm.
- Connectivity: Optional.
- Consumibles: 1220 toner.
- Usage: Office.
- Official drivers