Honeywell PC42d Compacta error RIBBON-OUT: How to Fix
The Honeywell PC42d Compacta error RIBBON-OUT is a warning that the internal sensor has failed to detect the presence of thermal transfer ribbon. This message is displayed primarily when the supply roll is exhausted or if the print settings do not match the loaded material. To resolve this, it is essential to verify both the physical installation of the ribbon and the configuration settings within your printer driver.
Common causes
- 1Exhausted ribbon roll.
- 2Driver/Material mode mismatch.
- 3Sensor debris buildup.
- 4Improper spool tension.
Solutions
Quick Diagnosis
If the error persists despite a full ribbon roll, it is likely that the sensor is obscured by debris or the driver mode is incorrectly set to thermal transfer.Steps to follow
- 1
Check ribbon
Verify the thermal transfer ribbon is correctly loaded and threaded.
- 2
Clean sensor
Gently clean the ribbon sensor with compressed air or a dry swab.
- 3
Check driver settings
Ensure the printer driver is set to the correct printing mode (Direct Thermal vs Thermal Transfer).
Frequently asked questions
The internal sensor detects no ribbon, either because it's finished or the print mode is mismatched.
If you are printing in direct thermal mode, simply update the driver configuration.
The printer uses standard wax or wax-resin thermal ribbons.
Regularly clean the sensors and verify ribbon alignment before printing.