Fujitsu fi-6671 error E006: Troubleshooting Guide
The Fujitsu fi-6671 error E006 is a standard notification alerting the user to an obstruction in the document transport mechanism. This error prevents the scanner from completing a batch because the system registers that a sheet has stalled in the feed path. Fixing Fujitsu fi-6671 error E006 mostly involves clearing jams and keeping the feed components clean.
Common causes
- 1Document jam within the ADF path.
- 2Excessive dust on rubber feed rollers.
- 3Foreign objects like staples or paper clips.
- 4Worn-out separation pad causing multi-feed.
Solutions
Quick Diagnosis
If the machine stops and displays E006, check for debris such as staples or adhesive residues from labels. A failure in the sensor to clear the path will trigger this alert.Step-by-Step Solution
- Lift the ADF hatch to expose the document path.
- Remove jammed papers slowly to prevent damage to the optical components.
- Clean the rollers with a soft cloth and manufacturer-approved cleaner.
- Close the hatch and perform a test scan to clear the status code.
Prevention and Maintenance
Perform regular cleaning of rubber rollers. Replace the pick rollers once they show signs of becoming slick or hardened. Use only original cleaning chemicals.When to Call a Technician
If the error occurs consistently even without paper inside, the motor driving the ADF or an internal sensor might require professional inspection.Device Technical Data
- Technology: ADF production scanner.
- Speed: Up to 70 ppm.
- Interface: SCSI-3, USB 2.0.
- ADF Capacity: 200 sheets.
- Consumable: Roller replacement kit.
- Use: Document archiving workflows.
- Support Center
Steps to follow
- 1
Open scanner lid
Open the top cover to access the paper feed path.
- 2
Clear jam
Gently remove any trapped documents.
- 3
Clean rollers
Use an official cleaning agent to remove dirt from the rubber feed rollers.
Frequently asked questions
The error E006 indicates a paper jam or failing pickup rollers that cannot advance the document.
Usually not, it's a common maintenance issue requiring only a cleanup of the rollers or jam removal.
Regularly wipe the pick rollers with authorized cleaner and replace the separation pad every 5k-10k sheets.
Replacement roller kits can be bought from official Fujitsu service providers.