Kyocera TASKalfa Pro 15000c Error C5800: Fan Failure
The Kyocera TASKalfa Pro 15000c error C5800 triggers when the system detects that one of the cooling fans is not rotating at the correct RPM. This warning is a vital safety measure to protect internal circuitry and ink quality. If this error appears, airflow is compromised, which can degrade the performance of your production machine. Follow these steps to verify your ventilation status.
Common causes
- 1Excessive dust accumulation physically blocking fan blade rotation.
- 2Electrical fan motor failure due to end-of-life.
- 3Accidental disconnection of the fan cable after a previous intervention.
- 4Faulty RPM monitoring sensor providing false low-speed data.
Solutions
Diagnóstico rápido
The C5800 error manifests as a touchscreen lock-up following a loud or intermittent fan noise. Often, the issue occurs in machines operating in dusty environments, causing residue to accumulate on fan blades.Solución paso a paso
- Clear Vents: Ensure no ventilation grids are obstructed by walls or furniture.
- Power Reset: Turn off the machine completely for 10 minutes to allow natural cooling.
- Spin Check: Listen to see if a fan attempts to start but sounds stuck due to dust.
Prevención y mantenimiento
Vacuum the external grids monthly and ensure the working environment does not exceed 30°C. Preventative dust cleaning extends fan life and avoids critical blockages.Cuándo llamar a un técnico
If the C5800 error persists after cleaning external dust, the fan motor might be burned out or the RPM sensor disconnected. Replacing internal fans involves dismantling panels, which requires a technician.Ficha técnica del equipo
- Technology: High-speed inkjet (Production)
- Performance: 150 ppm
- Connectivity: Gigabit LAN
- Capacity: Heavy-duty (up to 14,310 sheets)
- Consumables: Genuine Kyocera Pro pigment inks
- Recommended Use: Industrial printing environments
- Drivers / Official Firmware
Steps to follow
- 1
Clear Vents
Ensure no ventilation grids are obstructed by walls or furniture.
- 2
Power Reset
Turn off the machine completely for 10 minutes to allow natural cooling.
- 3
Spin Check
Listen to see if a fan attempts to start but sounds stuck due to dust.
Frequently asked questions
This code indicates a failure in one of the internal cooling fans, which could lead to critical overheating.
You should stop using it; overheating can permanently damage the logic board or the ink injectors.
Non-genuine consumables may generate fine particles that clog ventilation filters.
Keep the area around the device clear and perform monthly external dust cleaning with gentle compressed air.