C260e-STUDIO 330ACHas video
Toshiba e-STUDIO 330AC Error C260 - Scanner Peak Fix
Error code C260 indicates that the exposure lamp peak detection on the Toshiba e-STUDIO 330AC has failed during initialization, preventing calibration against the standard white reference sheet.
1 views
Common causes
- 1Dirty scanning glass or contaminated white reference board.
- 2Defective exposure lamp or CIS optical module.
- 3Loose or faulty optical ribbon flat cable.
- 4Defective main system board (SYS).
Solutions
Actionable Maintenance and Solutions
This scanner error is predominantly due to superficial debris interfering with the optical reader. Work through these troubleshooting steps:
- Meticulous Optics Cleaning:
* Open the ADF unit.
* Clean the glass plate surface, specifically targeting the narrow slit glass (platen) utilizing a microfiber cloth.
* Locate the white calibration strip on the underside of the scanner frame. If dust, hair, or corrector fluid is present, scrub it off gently with isopropyl alcohol.
- Check Flat Ribbons:
* If basic cleaning fails, power down the system.
* The internal scanner flat harness connecting the optical carriage might need reseating or replacement by authorized service personnel.
Steps to follow
- 1
Clean optical path and platen
Wipe down all optics glass panels and clean the white reference guide line with a clean cloth.
- 2
Perform dry reboot
Shut down, disconnect auxiliary devices, power on again, and test scan functionality.
Videos
Frequently asked questions
A dirty white reference calibration strip on the optical system frame is the most common cause, triggering a sensor read failure.